BVVNC - KLEAN CRETE MASONRY CLEANER, GKC17

  • MSDS: BVVNC
  • Manufacturer: W M BARR AND CO INC
  • Product Name: KLEAN CRETE MASONRY CLEANER, GKC17
  • National Stock Number: 6850-00N053359
Product Identification

Product ID:KLEAN CRETE MASONRY CLEANER, GKC17
MSDS Date:07/20/1992
FSC:6850
NIIN:00N053359
MSDS Number: BVVNC

Responsible Party
W M BARR & CO INC
2105 CHANNEL AVE
MEMPHIS, TN 38113
US

Emergency Phone: 901-775-0100

Info Phone: 901-775-0100

Cage: IO117

Contractor
W.M. BARR & COMPANY/KLEAN-STRI, DIVISION OF
1879 MEMPHIS, TN 38101 US

Telephone: 901-775-0100

Cage: 91522

Ingredients

HYDROCHLORIC ACID (SARA III) (CONSISTING OF ING 2-4)

CAS: 7647-01-0

RTECS: MW4025000

Fraction By Weight: 15-20%

OSHA PEL 5 PPM, C

ACGIH TLV: 5 PPM, C

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


HYDROCHLORIC ACID; (HYDROGE CHLORIDE) (SARA III)

CAS: 7647-01-0

RTECS: MW4025000

Fraction By Weight: 30-35%

OSHA PEL 5 PPM, C

ACGIH TLV: 5 PPM, C

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


ETHANOL, 2-BUTOXY-; (ETHYLENE GLYCOL MONOBUTYL ETHER)

CAS: 111-76-2

RTECS: KJ8575000

Fraction By Weight: 1-5%

OSHA PEL 50 PPM, S

ACGIH TLV: 25 PPM, S


OCTYLPHENOXYPOLYETHOXYETHANOL SOLUTION CONSISTING OF ING 5

RTECS: 9999999ZZ

OSHA PEL N/K

ACGIH TLV: N/K


GLYCOLS, POLYETHYLENE,

CAS: 9036-19-5

RTECS: MD0907600

Fraction By Weight: 97-99%

OSHA PEL N/K

ACGIH TLV: N/K


AMMONIUM CHLORIDE (SARA III)

CAS: 12125-02-9

RTECS: BP4550000

Fraction By Weight: 1-5%

OSHA PEL 10 MG/M3; 20 STEL

ACGIH TLV: 10 MG/M3 FUME

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


17 G/L (EXCLUDING EXEMPT

RTECS: 9999999VO

OSHA PEL N/K

ACGIH TLV: N/K


ABSORB MATL & PLACE IN PLASTIC CNTNR WHERE

RTECS: 9999999ZZ


FOR TRANSPORTATION RELATED SPILLS CONTACT CHEMTREC

RTECS: 9999999ZZ


AIR ACROSS THE WORK AREA. IF STRONG ODOR IS

RTECS: 9999999ZZ


STOP. VENTILATION IS INADEQUATE. LEAVE AREA

RTECS: 9999999ZZ


EXPOS. A SOURCE OF CLEAN WATER SHOULD BE

RTECS: 9999999ZZ


EAT, DRINK OR SMOKE IN WORK AREA. BEFORE REUSE,

RTECS: 9999999ZZ


BY PRIOR USE. DISCARD ANY CLTHG/OTHER PROT EQUIP

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INHAL:MAY CAUSE DIZZ, HDCH,
IRRIT OF RESP TRACT, COUGH, VOMIT, NARCOS, BLOOD DMG & LIVER
INJURY. SKIN:IRRITANT. CAUSES SEV BURNS. MAY CAUSE BURNS, IRRIT,
REDNESS, SWELL, TISS DMG & MAY BE ABSORB ED READILY TO PRDCE SYMPS
SIMILAR TO EFTS OF INGEST. EYES: IRRITANT. CAUSES SEV BURNS.
INGEST: HARMFUL (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:IF SWALLOWED. MAY CAUSE DIZZ, HDCH,
NAUS, WEAK, VOMIT, BURNS IN MOUTH, PHARNYX, & GI TRACT, LOSS OF
COORDINATION, DIARR, SEV IRRIT, BURNS & PERFORATION OF INTESTINAL
TRACT & CHG IN WHITE BLOO D CELLS. CHRONIC:ANIMAL STUDIES HAVE
CLEARLY SHOWN DOSE-RELATED ADVERSE EFTS TO CNS, HEMATOPOIETIC TISS,
BLOOD, (SUPDAT)
Medical Cond Aggravated by Exposure:DISEASES OF THE SKIN.

First Aid

First Aid:INHAL: IF DFCLTY BRTHG, MOVE TO AIR FREE OF VAPS. ADMIN
OXYGEN/ARTF RESP UNTIL MED ASSISTANCE CAN BE RENDERED. SKIN: WASH
W/SOAP & LG QTYS OF WATER & SEEK MED ATTN IF IRRIT FROM CNTCT
PERSISTS. EYES: FLUSH W/LG QTYS WATER FOR AT LEAST 15 MIN & SEEK
IMMED MED ATTN. INGEST: GIVE LG QTYS WATER, MILK/MILK OF MAGNESIA
IMMED. DO NOT INDUCE VOMIT. CALL POIS CTL CTR, HOSPITAL EMER
ROOM/MD IMMED. (SUPDAT)

Fire Fighting

Extinguishing Media:USE CARBON DIOXIDE, DRY POWDER OR FOAM.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROT EQUIP
. STORAGE CNTNRS EXPOS TO FIRE SHOULD BE KEPT COOL W/WATER SPRAY TO
PVNT PRESS BUILD-UP.
Unusual Fire/Explosion Hazard:KEEP CONTAINER TIGHTLY CLOSED. STAY AWAY
FROM HEADS OF CONTAINERS THAT HAVE BEEN EXPOSED TO INTENSE HEAT OR
FLAME.

Accidental Release

Spill Release Procedures:KEEP UNNEC PEOPLE AWAY; ISOLATE HAZ AREA &
DENY ENTRY. STAY UPWIND, OUT OF LOW AREAS & VENT CLSD SPACES BEFORE
ENTERING. SHUT OFF IGNIT SOURCES; KEEP FLARES, SMKNG/FLAMES OUT OF
HAZ AREA. SM SPILLS: T AKE UP LIQ W/SAND, EARTH/OTHER NONCOMBUST
(ING 8)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:PROTECT FROM FREEZING. AVOID EXTREME
HIGH OR LOW TEMPERATURES.
Other Precautions:READ CAREFULLY ALL CAUTIONS & DIRECTIONS ON PRODUCT
LABEL BEFORE USE. SINCE EMPTY CNTNR RETAINS RESIDUE, FOLLOW ALL
LABEL WARNINGS EVEN AFTER CNTNR IS EMPTY. DISPOSE OF EMPTY CNTNR
ACCORDING TO ALL RE GS. DO NOT REUSE THIS CNTNR.

Exposure Controls

Respiratory Protection:USE ONLY W/ADEQ VENT UNDER ENGINEERED AIR CTL
SYS DESIGNED TO PVNT EXCEEDING APPROP TLV. FOR OCCAS USE, WHERE
ENGINEERED AIR CTL IS NOT FEASIBLE, USE PROPERLY MAINTAINED &
FITTED NIOSH/MSHA APPRVD RES P. DUST MASK DOES NOT PROT AGAINST
VAPS.
Ventilation:USE ONLY W/ADEQ VENT TO PVNT BUILD-UP OF VAPS. OPEN ALL
WINDOWS & DOOR. USE ONLY W/CROSS VENT OF MOVING FRESH (ING 10)
Protective Gloves:IMPERMEABLE GLOVES.
Eye Protection:ANSI APPRVD GOGGLE & FACESHIELDS .
Other Protective Equipment:VARIOUS APPLICATN METHS DICTATE USE OF ADDNL
PROT SFTY EQUIP SUCH AS IMPERMEABLE APRONS, ETC. TO MINIMIZE (ING
12)
Work Hygienic Practices:WASH HANDS THOROUGHLY AFTER USE. CONTACT LENSES
SHOULD NOT BE WORN WHILE WORKING WITH CHEMICALS.
Supplemental Safety and Health
% VOLAT: 99.5(WT). MATL TO AVOID: FLAM HYDROGEN GAS). EFTS OF
OVEREXP:KIDNEYS & LIVER, ASSOC W/ADMIN OF 2-BUTOXYETHANOL.
(EXTRACTED FROM DHHS (NIOSH) PUBLICATION NO. 90-118) . PRLNG/RPTD
CNTCT M AY CAUSE DERM. FIRST AID PROC:NOTE TO MD:FORMULA IS
REGISTERED W/POISINDEX. CALL LOC POIS CTL CTR FOR FURTHER INFO.

Chemical Properties

Boiling Pt:B.P. Text:>123F,>51C
Vapor Pres:1 @ 20C
Vapor Density:HVR/AIR
Spec Gravity:1.034
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:SUPDAT

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS, STRONG CAUSTICS, ALKALI & ALKALI METAL,
CYANIDES & COMMON & ACTIVE METALS (WHICH PRDCE (SUPDAT)
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:THERMAL DECOMPOSITION MAY PRODUCE
HYDROGEN CHLORIDE VAPORS.

Disposal

Waste Disposal Methods:DISPOSE IN ACCORDANCE WITH APPLICABLE LOCAL,
STATE AND FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.